REV-27-105
This premium performance 12V dry series battery is equipped with an M8 terminal type and has more capacity than traditional lead-acid batteries, even in extreme conditions. All RELiON R4000 batteries have installation flexibility. These non-hazardous, clean batteries emit no gasses during normal operation. They can be used safely near sensitive equipment or people.
PRODUCT SPECIFICATIONS
- Voltage: 12.0V
- Amp Hours: 105Ah
DIMENSIONS & WEIGHT
- Length: 12 in (306 mm)
- Width: 6.6 in (168 mm)
- Height: 8.4 in (214 mm)
- Weight: 59.7 lbs (27.1 kg)
APPLICATIONS
- Backup Power
- Electric Vehicles
- Marine
- Recreational Vehicles
- Solar
DATA SHEET
ELECTRICAL SPECIFICATIONS |
|
---|---|
Nominal Voltage | 12 V |
Capacity @ C100 | 110 Ah |
Capacity @ C20 | 105 Ah |
Capacity @ C10 | 99 Ah |
Capacity @ C5 | 89 Ah |
Capacity @ 75A | 50 min |
Capacity @ 25A | 204 min |
Energy @ C100 | 1320 Wh |
Internal Resistance | 5.72 mΩ |
Short Circuit Current | 2600 A |
Self Discharge | <3% per Month |
MECHANICAL & PHYSICAL SPECIFICATIONS |
|
---|---|
Dimensions | 12.1 x 6.6 x 8.4” 306 x 168 x 214 mm |
Weight | 59.8 lbs (27.1 kg) |
Terminal Type | M8 |
Terminal Torque | 85 – 95 in-lbs (10 – 11 N-m) |
Battery Type | VRLA |
Case Material | ABS |
Handle | Plastic |
CHARGE SPECIFICATIONS |
|
---|---|
Recommended Charge Current | 11 – 21 A |
Maximum Charge Current | 26 A |
TEMPERATURE SPECIFICATIONS |
|
---|---|
Operation/Storage Temperature Range | -4 – 122 ºF (-20 – 50 ºC) |
COMPLIANCE SPECIFICATIONS |
|
---|---|
Shipping Classification | UN 2800, CLASS 8 |
CHARGE VOLTAGES (12 V SYSTEMS) |
|
---|---|
Bulk/Absorption | 14.4 V – 14.7 V |
Float | 13.6 – 13.8 V |
CHARGE VOLTAGES (24 V SYSTEMS) |
|
---|---|
Bulk/Absorption | 28.8 V – 29.4 V |
Float | 27.2 – 27.6 V |
CHARGE VOLTAGES (36 V SYSTEMS) |
|
---|---|
Bulk/Absorption | 3.2 V – 44.1 V |
Float | 40.8 – 41.4 V |
CHARGE VOLTAGES (48 V SYSTEMS) |
|
---|---|
Bulk/Absorption | 57.6 V – 58.8 V |
Float | 54.4 – 55.2 V |
CHARGE TEMPERATURE COMPENSATION |
|
---|---|
Cold Temperature Charging | +2.8 mV/cell/ºF +5 mV/cell/ºC |
Hot Temperature Charging | -2.8 mV/cell/ºF -5 mV/cell/ºC |